Quartz control plates for calibration of polarimeter

1.) Quartz control plates for calibration of polarimeter

Accessories for quartz control plates

  • Temperature sensor for automatic temperature correction. 
  • Only to be used with new M- and H-series and new Saccharomat models with plug!
  • Replacement of the factory certificate (only for quartz plates in good shape and no changes are necessary).
  • Official certificate for quartz control plates can be supplied by the German Institut of Metrology (PTB) on their actual charges.

Body 1

Single quartz control plate

ID-N°: 00613 Quartz control plates, single, -30°Z (±1°Z)
ID-N°: 00616 Quartz control plates, single, +25°Z (±1°Z)
ID-N°: 00618 Quartz control plates, single, +50°Z (±1°Z)
ID-N°: 00619 Quartz control plates, single, +75°Z (±1°Z)
ID-N°: 00621 Quartz control plates, single, +99°Z (±1°Z)

Double quartz control plate

ID-N°: 00614 Quartz control plates, double, +15°Z (±1°Z)
ID-N°: 00615 Quartz control plates, double, +20°Z (±1°Z)


https://vimeo.com/136604308

2.) Temperatue sensor for Quartz Control Plate

Accessories for quartz control plates

  • Temperature sensor for automatic temperature correction. 
  • Only to be used with new M- and H-series and new Saccharomat models with plug!
  • Replacement of the factory certificate (only for quartz plates in good shape and no changes are necessary).
  • Official certificate for quartz control plates can be supplied by the German Institut of Metrology (PTB) on their actual charges.

Body

Accessories for quartz control plates

ID-N°: 07277 Temperature sensor

https://vimeo.com/136604308

3.) Triple quartz control plates

Triple quartz control plates for polarimeter calibration and verification In addition of Single Quartz Control Plates (SQCP) SCHMIDT + HAENSCH is now announcing new Triple Quartz Control Plates. They are consisting of one left and one right turning quartz plate, mounted in separate housing. They can be used together for a combined rotation. That means that one plate is on the left and one on the right side of the holder. If removed one plate from the holder, plates can be used separately. Each QCP, manufactured by SCHMIDT + HAENSCH, comes with a factory certificate showing calibration at 7 different wavelengths and traceability to PTB not older than two years. Five models are available.

Triple Quartz Control Plates TQCP

Order number: 10431 TQCP 15 + 15°Z / +5.25 angular degree (°)

SQCP +45°Z / +15.75 ° 
SQCP -30°Z / -10.5 ° 
Order number: 10432 TQCP 20 + 20°Z / +7 angular degree (°)

SQCP +50°Z / +17.5 °
SQCP -30°Z / -10.5 ° 
Order number: 10433 TQCP 45 + 45°Z /+15.75 angular degree (°)

SQCP +75°Z / +26.25 °
SQCP -30°Z / -10.5 ° 
Order number: 10434 TQCP 69.5 + 69.5°Z / +24.33 angular degree (°)

SQCP +99.5°Z / +34.65 °
SQCP -30°Z / -10.5 ° 
Order number: 10430 TQCP 5 + 5°Z / +1.75 angular degree (°)

SQCP +30°Z / +10.5 °
SQCP -25°Z / -8.75 ° 